The uses and testing methods of a free expansion tester


Release Date:

2020-11-25

Purpose of the free swell test instrument: The free swell rate is the ratio of the difference between the volume of loose dry granular soil accumulated freely in water and air to the volume accumulated in air, expressed as a percentage.

Free Swelling Test Apparatus Purpose:

       Free swell is the ratio of the difference between the volume of loose, dry, granular soil accumulated freely in water and the volume accumulated in air, expressed as a percentage, used to determine the swelling of loose soil particles in water without structural force. This test method is suitable for expansive soils.

   Free Swelling Test Apparatus Test Method:

      1. Take a representative sample of the soil and crush it, then pass it through 0.5mm a sieve. After mixing evenly, put about 50g into the soil box, move it to the oven, and bake it at 105-110℃ until constant weight is reached. After taking it out, put it in a desiccator and cool it to room temperature.

      2. Install Free Swelling Test Apparatus a neckless funnel on the funnel frame, and place the soil measuring cup in the ring on the base plate so that the bottom of the funnel is aligned with the measuring cup. The supplier, Hebei Dahong Experimental Instrument Co., Ltd., adjusts the funnel. The distance between the bottom of the funnel and the spout of the measuring cup is 10mm。

      3. Take out the soil sample from the desiccator, pour the soil sample into the measuring cup with a spoon, scrape off the soil surface along the cup mouth after filling, pour the soil sample in the measuring cup into the measuring spoon, then measure the soil measuring cup is centered under the neckless funnel, pour the soil sample in the spoon into the funnel at one time, and then gently stir it in the funnel with a thin glass or wire until it is all leaked out. Gently scrape with a flat knife perpendicular to the mouth of the cup, remove the excess soil sample (to prevent vibration), and record the mass of the soil in the cup.

 Free Swelling Test Apparatus

      4. Weigh the next sample in the same way as above and perform parallel measurements. The difference between the two masses should not be greater than 0.1g。

      5. Install 30ml Distilled water is poured into a glass graduated cylinder, and 5ml is added 5 (% analytically pure sodium chloride) solution, and then the soil sample in the measuring cup is poured into the glass graduated cylinder.

      6. Stir the suspension in the cylinder with a stirrer. The stirrer should reach the bottom of the liquid level and stir 10 times (approximately 10S ). Wash the dirt particles attached to the mixer into the cylinder, and then rinse the inner wall of the cylinder to make the cylinder. The internal liquid level is approximately 50 ml mark.

      7. After the soil sample accumulates in the cylinder, record the volume of the sample approximately every 5 hour. The estimated volume is 0.1 ml . When reading, the line of sight and the soil surface must be on the same plane, and the difference between the two readings should not be greater than 0.2 It is considered that the swelling is stable. Use this stable reading to calculate the free swell.